Banks, insurers, investment firms and payment companies in the European Union have been under the Digital Operational Resilience Act (DORA) since 17 January 2025. Many of them have been told to “meet the DORA logging requirements” and then found that DORA itself says almost nothing about logs. The detail sits in a separate technical rulebook, and much of what circulates online mixes up its article numbers or adds a retention period that no official text contains.
This guide sets out the DORA logging requirements from the official texts: what to log, how to protect it, how long to keep it, and how logs feed the incident reporting deadlines. We build UTMStack, a SIEM (security information and event management) tool, so weigh our view accordingly. Most of this guide is about the law, not our product.
The short answer: DORA, Regulation (EU) 2022/2554, uses the word “log” only once. The real logging rules are in Article 12, “Logging”, of Commission Delegated Regulation (EU) 2024/1774, the regulatory technical standards (RTS) on ICT (information and communication technology) risk management. It says to document and run logging procedures for five kinds of events: access control and identity, capacity management, change management, ICT operations, and network traffic. Logs must be protected against tampering and deletion, logging failures must be detected, and all clocks must follow one documented time source. There is no fixed retention period: each firm sets its own, based on risk. Article 23 then says to analyse the logs and alert on anomalies, outside working hours too. A major incident must be reported within 4 hours of being classified as major, and within 24 hours of becoming aware of it.
Where the DORA logging rules live
One regulation sets the duties; a delegated regulation spells out the logging detail
Article 9: monitor ICT systems continuously. Article 10: detect anomalous activity. Article 17: record every ICT-related incident. The word "log" appears once, in Article 17(3)(b).
Which events to log, how much detail, how to protect logs, how to notice when logging fails, clock synchronisation, and a retention period you set yourself.
Collect and analyse the logs, alert on anomalies, prioritise alerts outside working hours, and alert when log collection breaks.
Where the DORA logging rules actually live
DORA sets the duties in broad terms. Article 9(1) says financial entities “shall continuously monitor and control the security and functioning of ICT systems and tools”. Article 10 asks for mechanisms “to promptly detect anomalous activities”, with automatic alerts for incident staff. Article 17(2) says firms “shall record all ICT-related incidents and significant cyber threats”.
The detail was drafted by the European Supervisory Authorities (ESAs), the three EU regulators for banking, insurance and securities markets. The Commission adopted it as Delegated Regulation (EU) 2024/1774, which entered into force on 15 July 2024. Like DORA, it is a regulation, so it applies directly in every member state.
| Text | Article | What it says about logs |
|---|---|---|
| DORA, Regulation (EU) 2022/2554 | Articles 9, 10 and 17 | Monitor continuously, detect anomalies, record all incidents. Logging is implied, not described |
| RTS 2024/1774 | Article 12 “Logging” | The full logging duty: events, detail, protection, failure detection, clocks, retention |
| RTS 2024/1774 | Article 21 “Access control” | Log who is allowed into premises, data centres and sensitive areas, and keep users identifiable for their actions |
| RTS 2024/1774 | Article 23 | Collect and analyse “at least the logs collected in accordance with Article 12”, and raise alerts |
| Delegated Regulation (EU) 2025/301 | Article 5 | Deadlines for the initial, intermediate and final incident reports |
A common mix-up. People search for “DORA Article 12 logging”, but Article 12 of DORA itself is about backups, restoration and recovery. The logging article is Article 12 of the RTS, Delegated Regulation 2024/1774. If a policy or contract cites “DORA Article 12” for logging, it points at the wrong text.
Who has to follow them
DORA Article 2 lists 20 types of financial entity, from banks, payment and electronic money institutions and investment firms to crypto-asset service providers, trading venues, insurers, pension funds, fund managers and crowdfunding platforms. A few are left out, such as pension funds whose schemes together have no more than 15 members and insurance intermediaries that are micro, small or medium-sized businesses.
Not every firm gets the same logging rule. DORA Article 16(1) puts some smaller firms under a simplified framework: small and non-interconnected investment firms, exempted payment and electronic money institutions, some exempted credit institutions, and small occupational pension funds. For them, RTS Article 34(f) only asks them to log access control, ICT operations, system and network traffic, and ICT change management, with no separate rules on log protection, clocks or retention.
Which DORA logging rule applies to you?
Start from DORA Article 2, then check the simplified framework list in Article 16(1)
DORA also overlaps with NIS2, the EU’s general cybersecurity directive, Directive (EU) 2022/2555. Article 1(2) of DORA says that, for financial entities that NIS2 treats as essential or important, DORA is a “sector-specific Union legal act”. Recital 28 of NIS2 spells out the result: DORA’s rules on ICT risk management, incident management and incident reporting “should apply instead of those provided for in this Directive”. Our guide to NIS2 logging requirements covers the general regime.
What RTS Article 12 says to log
Article 12(1) says financial entities shall “develop, document, and implement logging procedures, protocols and tools.” Article 12(2) lists what those procedures must contain. Point (c) is the list of events, mapped below to the log sources that usually cover them.
| Article 12(2)(c) event category | Typical log sources | What it helps you catch |
|---|---|---|
| Logical and physical access control, and identity management | Active Directory and Entra ID sign-ins, VPN logins, privileged access, badge and door systems | Stolen credentials, misuse of administrator accounts, someone reaching hardware directly |
| Capacity management | Server and storage metrics, database and application capacity alerts | Resource exhaustion and denial of service before it becomes an outage |
| Change management | Configuration changes, software installs, firewall rule changes, cloud audit logs | Unapproved changes and tampering meant to weaken defences |
| ICT operations, including system activity | Operating system logs, scheduled jobs, backup job results, service starts and stops | Persistence, failed backups, disabled security tools |
| Network traffic, including network performance | Firewall and proxy logs, flow records, intrusion detection alerts | Scanning, unexpected outbound connections, data leaving the network |
The rest of Article 12(2) adds five more duties, shown here with point (c).
RTS Article 12(2) in six duties
What your written logging procedures must cover, point by point
Which events you log, how long you keep the logs, and how you secure and handle the log data.
Detail that fits the purpose of each log and is good enough to detect anomalous activity.
Access and identity, capacity, change, ICT operations, and network traffic.
Against tampering, deletion and unauthorised access, at rest, in transit and, where relevant, in use.
Measures to detect a failure of logging systems.
Every ICT system's clock synchronised to a documented, reliable reference time source.
Two of these are often missed. Point (e) means a quiet log source is a finding: if a domain controller stops sending events, you must be able to tell. Point (f) means timestamps must line up across systems, or you cannot rebuild the order of events in an incident.
The retention myth
Many web pages say DORA requires logs to be kept for five years. We checked DORA and its delegated and implementing regulations, and none gives a number of months or years for keeping logs.
What the RTS says is in the closing sentence of Article 12(2): firms “shall establish the retention period, taking into account the business and information security objectives, the reason for recording the event in the logs, and the results of the ICT risk assessment.” Article 21, on access control, repeats the same wording. For incident evidence, Article 22(d) says to keep it “for a period that shall be no longer than necessary” for its purpose, in line with the recurring incident rule described below.
“Five years” appears in DORA three times, and never about logs: a joint ESA report every five years (Article 44(2)), how long published penalty decisions stay online (Article 54(6)), and the Commission’s power to adopt delegated acts (Article 57(2)). Other laws may set periods for certain records, but do not cite DORA for a number it does not contain.
The incident rules still give a practical floor. Article 8(2) of Delegated Regulation (EU) 2024/1772 treats repeated incidents with the same apparent root cause as one major incident when they “have occurred at least twice within 6 months” and together meet the major incident criteria. Most firms must check for this monthly (microenterprises and Article 16(1) firms are left out). Its Article 3(1) measures an incident’s duration from “the moment the incident is recorded in network or system logs” when it started before detection. In our reading, keeping less than six months of logs makes both checks hard. Many firms choose twelve months or more, and write down why. Data protection law pulls the other way for logs that contain personal data; our guide to GDPR log retention explains how to set a period that satisfies both.
What RTS Article 23 adds: watching the logs
Article 12 is about having logs. Article 23 is about using them:
- Collect and analyse. Article 23(2)(a) says to “collect, monitor, and analyse” internal and external factors, “including at least the logs collected in accordance with Article 12”, plus threat intelligence and incident notices from ICT providers.
- Alert on anomalies. Point (b) asks for tools “generating alerts for anomalous activities and behaviour”, at least for assets that support critical or important functions.
- Outside working hours too. Point (c) says alerts must be prioritised “both during and outside working hours”.
- Alert when log collection breaks. The closing text asks for automated alerts on “anomalies affecting the completeness and integrity of the data sources or log collection”.
- Record three facts per anomaly. Article 23(4): the date and time it occurred, the date and time it was detected, and its type.
- Protect the records against tampering and unauthorised access, at rest, in transit and, where relevant, in use (Article 23(3)).
This is the part of DORA that most closely describes a SIEM: logs in one place, rules that raise alerts, a record of when each alert happened, and checks that the feeds still flow. DORA names no product, though.
Why the 4 hour clock needs logs
Delegated Regulation (EU) 2025/301 sets the reporting deadlines for major ICT-related incidents.
The DORA major incident reporting clock
Deadlines from Article 5(1) of Delegated Regulation (EU) 2025/301
- Within 4 hoursInitial notification
From classifying the incident as major, and no later than 24 hours after becoming aware of it. It must give the date and time of detection.
- Within 72 hoursIntermediate report
From the initial notification. It adds the date and time the incident occurred and indicators of compromise.
- Within 1 monthFinal report
From the latest intermediate report. It gives the root cause and when the incident was resolved.
Each report asks for facts that come from logs: when you detected the incident, when it really started, which addresses and files were involved. If the logs are scattered, or kept only on the device that was attacked, gathering that within hours is unrealistic. Reports due on a weekend or holiday may wait until noon on the next working day (Article 5(4)), but not the initial and intermediate reports of credit institutions, central counterparties, trading venue operators and NIS2 essential or important entities (Article 5(5)).
A DORA logging checklist
Use this as a starting point for your written logging procedure under RTS Article 12:
- List the events you log for each of the five categories, by system, and mark the systems that support critical or important functions.
- Set and justify a retention period from your ICT risk assessment and any other law you are under.
- Send logs off the source system as events happen, to a central store that system administrators cannot change.
- Protect the store: encryption, restricted read access, no edit rights, deletion only by the retention schedule.
- Alert on silence when a source stops sending logs, as Articles 12(2)(e) and 23(2) ask.
- Synchronise clocks to one documented time source.
- Write detection rules for critical or important functions, with someone able to act on alerts at night.
- Test it once a year: pull logs from the oldest month your policy promises, and replay a past incident against the 4 hour deadline.
How UTMStack fits, and where it stops
A limit first: UTMStack does not ship a DORA framework, a mapping to Delegated Regulation 2024/1774, or regulator report templates. It scores nine other frameworks, including GDPR, ISO 27001, NIST and a Banking Security Audit checklist, and you can add your own controls. GDPR and CMMC 2.0 are free in the Community edition; the others need Enterprise. What it does is much of the technical work that Articles 12 and 23 describe:
- Most of the five event categories in one place. Identity activity from Active Directory, Linux, Microsoft Entra ID (through the Azure integration), Microsoft 365, Google Cloud and AWS; configuration changes from Windows, Linux audit logs, cloud audit trails and common firewalls; network traffic from firewalls and NetFlow or IPFIX flow records. See what logs should be sent to a SIEM.
- Detection as logs arrive. More than 600 detection rules mapped to MITRE ATT&CK, the public catalogue of attacker techniques, check each log against the rules for its source as it arrives. Each alert records its own time, the times of the events behind it, and its rule, category, technique and severity, which covers Article 23(4). See threat detection.
- Alerts at any hour, and incidents with a history. New alerts and incidents can be emailed to a list of addresses, and response flows can call any web address to reach chat or paging tools. Incidents keep status, severity, assignee, notes and a dated history. Deciding whether an incident is major, and reporting it, stays manual. If nobody watches alerts at night, our SOC Extension service can back up your own team.
- Retention you define. Retention is set in days for each dataset; a new install keeps logs for 730 days. Older records can move to cold storage and stay searchable without a restore. See log management.
- Your choice of location. UTMStack Cloud is a dedicated instance per customer on OVHcloud, with France or Poland for European Union customers, or you can run it self-hosted, including air-gapped.
Where it stops, said plainly:
- No alert when a source goes silent. The data sources page shows each source as live, idle or offline, rules alert when a log shows auditing switched off or a log cleared, and a scheduled compliance report flags logged logging failures. But there is no automatic alert when a source simply stops sending, which Article 23(2) asks for, so you need your own check. The syslog Forwarder also keeps no buffer during a server outage.
- Log protection is partly up to your platform. Logs travel to the server encrypted, access is controlled by roles, and console actions such as sign-ins and retention changes are audited. But agents skip the server certificate check by default, plain syslog is accepted from devices, stored logs get no built-in encryption, hashing or write-once protection, and running a search is not audited. Add disk encryption and storage locking where you host it.
- Two event categories need other tools. The agent does not collect CPU, memory or disk usage, so capacity management needs a monitoring tool. There is no built-in integration for badge readers or door controllers; one that sends syslog or JSON can be added with a custom parser.
- Clocks are yours. UTMStack stores times in universal time but does not set up a time server or measure clock drift. Its compliance report flags logged time synchronisation failures.
No tool makes a firm DORA compliant on its own; most of DORA is governance, testing and third-party risk. See our guide to SIEM and compliance and the compliance overview.
Frequently asked questions
Does DORA require a SIEM? No. DORA and its technical standards do not name any product type. They require logging, continuous monitoring, anomaly detection with alerts, and fast incident reporting. A SIEM is a common way to do that across many systems, but the law leaves the choice to you.
How long must logs be kept under DORA? There is no fixed period. RTS 2024/1774 Article 12 says each firm sets its own retention period based on business and security goals, why the event is logged, and its ICT risk assessment. The five years often quoted online is not in any DORA text.
What is DORA Article 12? Article 12 of DORA itself covers backup policies, restoration and recovery. The logging article people usually mean is Article 12 of Delegated Regulation (EU) 2024/1774, the RTS on ICT risk management, which is titled “Logging”.
Do DORA logging rules apply to ICT providers? Not directly, unless the provider is itself a financial entity. Banks and other financial entities pass the duties on through contracts: DORA Article 30 requires contracts for critical or important functions to give the firm and its supervisor “unrestricted rights of access, inspection and audit”. Providers designated as critical are also overseen by an EU Lead Overseer, which under Delegated Regulation (EU) 2025/295 can ask for extracts from their log management systems.
Sources
- Regulation (EU) 2022/2554 (DORA): https://eur-lex.europa.eu/eli/reg/2022/2554/oj
- Commission Delegated Regulation (EU) 2024/1774, RTS on ICT risk management: https://eur-lex.europa.eu/eli/reg_del/2024/1774/oj
- Corrigendum to Delegated Regulation (EU) 2024/1774 (15 May 2025): https://eur-lex.europa.eu/eli/reg_del/2024/1774/corrigendum/2025-05-15/oj
- Commission Delegated Regulation (EU) 2024/1772, classification of ICT-related incidents: https://eur-lex.europa.eu/eli/reg_del/2024/1772/oj
- Commission Delegated Regulation (EU) 2025/301, content and time limits for incident reports: https://eur-lex.europa.eu/eli/reg_del/2025/301/oj
- Commission Delegated Regulation (EU) 2025/295, oversight of critical ICT third-party service providers: https://eur-lex.europa.eu/eli/reg_del/2025/295/oj
- Directive (EU) 2022/2555 (NIS2), Recital 28: https://eur-lex.europa.eu/eli/dir/2022/2555/oj
- European Securities and Markets Authority, Digital Operational Resilience Act page: https://www.esma.europa.eu/esmas-activities/digital-finance-and-innovation/digital-operational-resilience-act-dora